S7_200_PC_ACCESS_V1_SP5_SP6

我把该软件卸载后 再安装 就安装不上了 一直报错误 哪位师傅知道怎么回事  又该如何装

图片说明:

S7_200_PC_ACCESS_V1_SP5_SP6   

最佳答案

正确的安装步骤:
Both S7-200 PC Access and STEP 7- Micro/WIN are installed
You must upgrade both applications to the latest versions for correct operation.
1) Contact Siemens customer support and obtain access to both upgrade installations from a Siemens FTP server.
2) Run either the STEP 7- Micro/WIN V4.0 SP9 upgrade or the S7-200 PC Access V1.0 SP6 upgrade.
3) Uninstall STEP 7- Micro/WIN.
4) Uninstall S7-200 PC Access.
5) Run STEP 7- Micro/WIN V4.0 SP9 upgrade.
6) Run S7-200 PC Access V1.0 SP6 upgrade.
 A previous version of only one application is installed and you want to install the latest version of the other application
For example, an older version of the STEP7- Micro/WIN is installed and you want the latest version of S7-200 PC Access. You must upgrade the old application to the latest version and then install the latest individual license version for the new application. Upgrading the old application is necessary for correct operation.

提问者对于答案的评价:

专家置评

建议直接安装完整包,目前pc access 的软件版本为pc access  v1.0 sp6完整安装包

原创文章,作者:more0621,如若转载,请注明出处:https://www.zhaoplc.com/plc179932.html

(0)
打赏 微信扫一扫 微信扫一扫 支付宝扫一扫 支付宝扫一扫
上一篇 2017年6月24日 下午6:37
下一篇 2017年6月24日

相关推荐