S7-200各种型号货号,以及模块货号

S7-200各种型号货号,以及模块货号

最佳答案

CPU222 DC/DC/DC,8输入/6输出6ES 7212–1AB23–0XB0 6ES7 212–1AB23–0XB8
CPU222 AC/DC/ Relay 8输入/6继电器6ES 7212–1BB23–0XB0 6ES7 212–1BB23–0XB8
CPU224 DC/DC/DC 14输入/10输出6ES 7214–1AD23–0XB0 6ES7 214–1AD23–0XB8
CPU224 AC/DC/ Relay 14输入/10继电器输出6ES 7214–1BD23–0XB0 6ES7 214–1BD23–0XB8
CPU224XP DC/DC/DC 14输入/10输出6ES 7214–2AD23–0XB0 6ES7 214–2AD23–0XB8
CPU224XPsi DC/DC/DC 14输入/10输出6ES7 214–2AS23–0XB0 6ES7 214–2AS23–0XB8
CPU224XP AC/DC/继电器14输入/10继电器输出6ES 7214–2BD23–0XB0 6ES7 214–2BD23–0XB8
CPU226 DC/DC/DC 24输入/16输出6ES 7216–2AD23–0XB0 6ES7 216–2AD23–0XB8
CPU226 AC/DC/ 继电器24输入/16继电器6ES 7216–2BD23–0XB0 6ES7 216–2BD23–0XB8
EM221 数字输入8x24VDC 6ES 7 2211BF220XA0 6ES7 221–1BF22–0XA8
EM221 数字输入16x24VDC 6ES 7 221–1BH22–0XA0 6ES7 221–1BH22–0XA8
EM222 数字输出8x24VDC 6ES 7 2221BF220XA0 6ES7 222–1BF22–0XA8
EM222 数字输出8x继电器6ES 7 2221HF220XA0 6ES7 222–1HF22–0XA8
EM223 24VDC 数字组合4输入/4输出6ES 7 2231BF220XA0 6ES7 223–1BF22–0XA8
EM223 24VDC数字组合4输入/4继电器输出6ES 7 2231HF220XA0 6ES7 223–1HF22–0XA8
EM223 24VDC数字组合8输入/8输出6ES7 223–1BH22–0XA0 6ES7 223–1BH22–0XA8
EM223 24VDC数字组合8输入/8继电器输出6ES 7 2231PH220XA0 6ES7 223–1PH22–0XA8
EM223 24VDC数字组合16输入/16输出6ES 7 2231BL220XA0 6ES7 223–1BL22–0XA8
EM 223 24VDC数字组合16输入/16继电器输出6ES 7 2231PL220XA0 6ES7 223–1PL22–0XA8
EM 223 24 VDC 数字组合32 输入/32 输出6ES7 223–1BM22–0XA0 6ES7 223–1BM22–0XA8
EM 223 24 VDC 数字组合32 输入/32 继电器输出6ES7 223–1PM22–0XA0 6ES7 223–1PM22–0XA8
EM231模拟量输入,4输入6ES 7 231–0HC22–0XA0 6ES7 231–0HC22–0XA8
EM235 模拟量组合,4输入/1输出6ES 7 235–0KD22–0XA0 6ES7 235–0KD22–0XA8
EM232模拟量输出,2输出6ES 7 232–0HB22–0XA0 6ES7 232–0HB22–0XA8
EM231模拟输入RTD,2输入6ES 7231–7PB22–0XA0 6ES7 231–7PB22–0XA8
EM231模拟输入热电偶,4输入6ES 7231–7PD22–0XA0 6ES7 231–7PD22–0XA8
6ES 7211–0AA23–0XB0 CPU221 24VDC 6 x 24 VDC 4 x 24VDC 1 否否否
6ES 7211–0BA23–0XB0 CPU221 120至240 VAC 6 x 24 VDC 4 x 继电器1 否否否
6ES 7212–1AB23–0XB0 CPU222 24VDC 8x24VDC 6 x 24 VDC 1 否否否
6ES 7212–1BB23–0XB0 CPU222 120至240 VAC 8x24VDC 6 x 继电器1 否否否
6ES 7214–1AD23–0XB0 CPU224 24VDC 14 x 24 VDC 10 x 24 VDC 1 否否是
6ES 7214–1BD23–0XB0 CPU224 120至240 VAC 14 x 24 VDC 10 x 继电器1 否否是
6ES 7214–2AD23–0XB0 CPU224XP 24VDC 14 x 24 VDC 10 x 24 VDC 2 2 1 是
6ES7 214–2AS23–0XB0 CPU 224XPsi 24VDC 14 x 24 VDC 10 x 24 VDC 2 2 1 是
6ES 7214–2BD23–0XB0 CPU224XP 120至240 VAC 14 x 24 VDC 10 x 继电器2 2 1 是
6ES 7216–2AD23–0XB0 CPU226 24VDC 24 x 24 VDC 16 x 24VDC 2 否否是
6ES 7216–2BD23–0XB0 CPU226 120至240 VAC 24 x 24 VDC 16 x 继电器2 否否是
表A–4 CPU常规规范
订货号模块名称及描述
尺寸(毫米)
(W x H x D)
重量功耗
电流供应
+5 VDC +24 VDC1
6ES 7211–0AA23–0XB0 CPU221 DC/DC/DC 6输入/4输出90 x 80 x 62 270 g 3W 0 mA 180 mA
6ES 7211–0BA23–0XB0 CPU221AC/DC/ Relay 6输入/4继电器90 x 80 x 62 310 g 6W 0 mA 180 mA
6ES 7212–1AB23–0XB0 CPU222 DC/DC/DC 8输入/6输出90 x 80 x 62 270 g 5W 340 mA 180 mA
6ES 7212–1BB23–0XB0 CPU222 AC/DC/ Relay 8输入/6继电器90 x 80 x 62 310 g 7 W 340 mA 180 mA
6ES 7214–1AD23–0XB0 CPU224 DC/DC/DC 14输入/10输出120.5 x 80 x 62 360 g 7 W 660 mA 280 mA
6ES 7214–1BD23–0XB0 CPU224 AC/DC/ Relay 14输入/10继电器输出120.5 x 80 x 62 410 g 10 W 660 mA 280 mA
6ES 7214–2AD23–0XB0 CPU224XP DC/DC/DC 14输入/10输出140 x 80 x 62 390 g 8 W 660 mA 280 mA
6ES7 214–2AS23–0XB0 CPU224XPsi DC/DC/DC 14输入/10输出140 x 80 x 62 390 g 8 W 660 mA 280 mA
6ES 7214–2BD23–0XB0 CPU224XP AC/DC/继电器14输入/10继电器输出140 x 80 x 62 440 g 11 W 660 mA 280 mA
6ES 7216–2AD23–0XB0 CPU226 DC/DC/DC 24输入/16输出196 x 80 x 62 550 g 11 W 1000 mA 400 mA
6ES 7216–2BD23–0XB0 CPU226 AC/DC/ 继电器24输入/16继电器196 x 80 x 62 660 g 17 W 1000 mA 400 mA
1 这

提问者对于答案的评价:
谢谢,刚入行

原创文章,作者:more0621,如若转载,请注明出处:https://www.zhaoplc.com/plc316804.html

(0)
打赏 微信扫一扫 微信扫一扫 支付宝扫一扫 支付宝扫一扫
上一篇 2020年11月1日
下一篇 2020年11月1日

相关推荐

  • 热电偶与热电阻问题求助。

    1.热电偶输出的是毫伏的电压信号是吧?输出的是多少毫伏到多少毫伏的的电压信号??K型热电偶的量程是0到多少度? 2.热电阻输出的是毫安的电流信号是吧?输出的是多少毫安到多…

    SIMATIC S7-200 2021年7月5日
  • s7_200 功能程序的编写,求助

    想用200编一段程序,想了很久没想出来,现求助采集cpu中的系统时间,第一天零点触发变量A(保持信号),第二天零点触发变量B(保持信号),并且复位A点,第三天零点触发变量A(保持信…

    SIMATIC S7-200 2018年12月5日
  • PPI接口与PPI协议

    看见资料上一会写PPI接口,一会又是PPI协议。想问是不是PPI接口也有,是一种电气规范,而PPi协议是使用PPI接口的协议? 最佳答案 PPI是通讯协议的名称,属于软件范畴。PP…

    SIMATIC S7-200 2021年7月5日
  • 200PLC MODBUS通讯,主站向从站写数据

    主站smart,从站200,通讯建立完成,主站可以从从站读取数据,主站向从站写数据adr40001,&400对应从站v0.0~等没有问题,可以将数据写入到从站,但我用adr…

    SIMATIC S7-200 2021年7月5日
  • 自由口发送字符串通信命令

    和一台功率仪器通信,功率仪器,能接受的为“:MEAS? W”,通过PLC模拟能发出,串口调试助手也能收到,但是用串口监视发现实际上PLC通信口发出的为如下:MEAS?&n…

    2017年6月10日
  • S7-200与与上位的的随机程序如何编写?

    我要做一个S7-200与上位机进行无线传输,传输的过程中,由于信号经常会断,客户要求信号断的时候要做一个信号报警。我想做一个随机做通信判断的,如果两者此时的信号不一致时就发报警。表…

    SIMATIC S7-200 2020年10月31日
  • EM277加不上去?

    GSD文件已安装(以前添加过),我是在已有的一个程序中进行修改,但我现在E277添加不上,采用的拖放方式。在总线上直接右键-插入对象可以添加,但不能选择通讯字节长度。 问题补充: …

    SIMATIC S7-200 2020年11月5日
  • 高速计数器的工作模式与输入端子是代表什么意思?

    谁能举一些比较实用的例子给我,最好附上说明(解释),谢谢了! 图片说明:    最佳答案 如果楼主没有接触过高速计数器功能,建议楼主先看一下面的视频,虽然介绍的…

    2021年7月5日
  • 西门子200与西门子700IE触摸屏总是通讯不上

    求大神帮助!关于西门子触摸屏与CPU224XP通讯,怎么设置也通讯不上,是用485通讯吗?485内部接线图,,视频教学选187.5,224XP不支持187.5波特率,选择其他的也都…

    2021年7月5日
  • S7200程序复位

    我在程序中用了PTO,如果在执行程序的时候,PTO子程序出错,我想让S7200发个故障信号给主机,然后主机给S7200一个复位信号,把故障清除掉,让程序重新开始执行,请问这个复位要…

    SIMATIC S7-200 2021年7月4日