Pcu50.3的数码管显示状态报警信息索取

Pcu50.3的数码管显示状态报警信息索取,请高手提供。

最佳答案

4DH MonoTonicCounter Initial Service case 
4EH CPU Middle Initial Service case 
4FH Multi-processor Middle Initial Service case 
50H SMBUS Driver Initial Service case 
51H SMART Timer Initial Service case 
52H RTC Initial Service case 
53H SATA Controller early initial Service case 
54H Setup SMM Control service Service case 
55H Setup Legacy Interrupt service Service case 
01H CPU power on and switch to Protected mode Service case 
02H Patching CPU microcode Service case 
03H Setup Cache as RAM Service case 
04H PCIE MMIO Base Address initial Service case 
05H CPU Generic Machine Status Register initial Service case 
06H Setup CPU speed Service case 
07H Cache as RAM test Service case 
08H Tune CPU frequency ratio to maximum level Service case 
09H Setup BIOS ROM cache Service case 
0AH Enter Boot Firmware Volume Service case 
70H Super I/O initial Service case 
71H CPU Early Initial Service case 
72H Multi-processor Early initial Service case 
73H HyperTransport initial Service case 
74H PCIE MMIO BAR Initial Service case 
75H North Bridge Early Initial Service case 
76H South Bridge Early Initial Service case 
77H PCIE Training Service case 
79H SMBUS Early Initial Service case 
41H South bridge Serial Peripheral Interface initial Service case 
42H Setup Reset service Service case 
43H South bridge Serial GPIO initial Service case 
44H Setup SMM ACCESS service Service case 
45H North bridge Middle initial Service case 
46H Super I/O DXE initial Service case 
47H Setup Legacy Region service Service case 
48H South Bridge Middle Initial Service case 
49H Identify Flash device Service case 
4AH Fault Tolerant Write verification Service case 
4BH Variable Service Initial Service case 
4CH Fail to initial Variable Service Service case 
26H Dispatch option ROMs Service case 
Get boot device information Service case 27H 
HD-Lock active Release lock: Set HD-lock to "Operating". 
28H End of boot selection Service case 
29H Enter Setup Menu Service case 
2AH Enter Boot manager Service case 
2BH Try to boot system to OS Service case 
2CH Shadow Misc Option ROM Service case 
2DH Save S3 resume required data in RAM Service case 
2EH Last Chipset initial before boot to OS Service case 
2FH Start to boot Legacy OS Service case 
30H Start to boot UEFI OS Service case 
31H Prepare to Boot to Legacy OS Service case 
32H Send END of POST Message to ME via HECI Service case 
33H Last Chipset initial before boot to Legacy OS. Service case 
34H Ready to Boot Legacy OS. Service case 
35H Fast recovery start flash Service case 
F9H No Boot Device Service case 
FBH UEFI Boot Start image Service case 
FDH Legacy 16 boot entry Service case 
FEH Try to Boot with INT 19 Service case 
E5H System wakeup from S5 Service case 
10H Enter Boot Device Selection entry Service case 
11H Install Hotkey service Service case 
12H Alert Standard Format Initial Service case 
13H PCI enumeration Service case 
14H PCI resource assign complete As a test, disable HW components in setup or remove 
expansion modules that have been installed. 
15H PCI enumeration complete Service case 
16H Keyboard Controller, Keyboard and Mouse initial Run a test by replacing the keyboard/mouse 
17H Video device initial Service case 
18H Error report device initial Service case 
19H USB host controller initial Service case 
1AH USB BUS driver initial Service case 
1BH USB device driver initial Service case 
1CH Console device initial fail Service case 
1DH Display logo or system information Service case 
1EH IDE controller initial Service case 
1FH SATA controller initial Service case 
20H Super IO controller initial Service case 
21H ISA BUS driver initial Service case 
22H Floppy device initial Service case 
23H Serial device initial Service case 
24H IDE device initial Service case 
25H AHCI device initial Service case 
56H Relocate SMM BASE Service case 
57H SMI test Service case 
58H VTD Initial Service case 
59H Legacy BIOS initial Service case 
5AH Legacy interrupt function initial Service case 
5BH ACPI Table Initial Service case 
5CH Setup SB SMM Dispatcher service Service case 
5DH Setup SB IOTRAP Service Service case 
5EH Build AMT (Active Management Technology) Table Service case 
5FH Processor Power Management Initial Service case 
60H Host Embedded Controller Interface Initial Service case 
61H Variable store garbage collection and reclaim 
operation 
Service case 
7AH Clock Generator Initial Service case 
7BH Internal Graphic device early initial, Service case 
7CH Host Embedded Controller Interface Initial Service case 
7DH Watchdog timer initial Service case 
7EH Memory Initial for Normal boot Replace the memory modules 
7FH Memory Initial for Crisis Recovery Replace the memory modules 
80H Simple Memory test Replace the memory modules 
81H Trusted Execution Technology function early initial Service case 
82H Start to use Memory Service case 
83H Set cache for physical memory Service case 
84H Recovery device initial Service case 
85H Found Recovery image Service case 
86H Recovery image not found Check whether the BIOS recovery image exists on the 
recovery medium (e.g. USB FlashDrive). 
87H Load Recovery Image complete Service case 
88H Start Flash BIOS with Recovery image Service case 
89H Loading BIOS image to RAM Service case 
8AH Loading Driver Execution Environment (DXE) core Service case 
8BH Enter DXE core Service case

提问者对于答案的评价:
谢谢

原创文章,作者:more0621,如若转载,请注明出处:https://www.zhaoplc.com/plc144490.html

(0)
打赏 微信扫一扫 微信扫一扫 支付宝扫一扫 支付宝扫一扫
上一篇 2017年6月2日 下午11:52
下一篇 2017年6月2日 下午11:52

相关推荐

  • 840D驱动手动优化

    在进行速度环测量时,提示无效的测量时间,可是,在测量参数里,没有测量时间的设定 最佳答案 楼主所说的速度环测量实际上就是速度环控制优化,即在时域的传统优化。但是在做速度环测量时,必…

    2017年11月1日
  • 更改34090时候会改变机床坐标

    想知道更改34090之后,机床坐标是否跟着改变。比如说,机床是根据设定好的坐标X:2350.333mm Y: 5892.3456mm Z:988.23…

    SINUMERIK 2018年12月14日
  • 840D刀库表问题

    机床维修后发现刀库表和刀具管理等软键变成了灰色,不能使用了。请问如何恢复?谢谢 。 问题补充:问了电工,说是总线插座松了,重新插过,可能是这个原因导致刀库表不能使用。如何…

    SINUMERIK 2017年12月7日
  • 840Dsl FB2读NC变量的问题

    我用TIA V16编写的840Dsl的PLC程序,FB2读取NC变量的说明书来编写程序读取NC变量,但是不成功,我打开别人用STEP7 V5.5编写的数控程序,…

    SINUMERIK 2020年10月31日
  • 绝对编码器与增量编码器比较

    绝对编码和增量编码是否都需要电池来保存断电后的位置信息,绝对编码与增量编码谁的反应速度更快?FUNAC机器人伺服系统采用什么编码? 最佳答案 1、编码器本身是不具备断电后保存位置信…

    SINUMERIK 2018年12月5日
  • 西门子系统 报警代码 120201 怎么解决?

    我们使用的是中捷的6913双面落地铣镗加工中心,西门子840D系统。近段时间,每天在使用一段时间后会出现“西门子系统 报警代码 120201 通信失败…

    SINUMERIK 2017年11月2日
  • 828D系统无实体刀库的情况下如何改变屏上的T刀号

    828D系统铣床版,无实体刀库,主轴上的刀具是人工安装在上面的;每次人工换上刀具后,执行一个指令,让HMI的T号改变,例如显示T1或T2等,只是起一个显示的功能,并无任何实际动作。…

    SINUMERIK 2020年10月31日
  • 840D数控系统如何截屏

    840D数控系统如何实现截屏?我按照840DSL的方法,按CTRL+P,完成之后不知道在哪找到图片文件? 版主推荐答案 hmi advanced存在f:\ALTMP文件名scfxx…

    SINUMERIK 2021年7月5日
  • 西门子802D系统无法传输程序与参数

    传输线检查无问题,通讯无通讯,用COM1端口。机台EUMAEV810,型号EV-F08166,求大神帮忙! 最佳答案 1.传输线按照《简明调试手册》上线序进行检查,最好采用屏蔽线;…

    SINUMERIK 2017年6月13日
  • 更换驱动模块后,230650报警必须进行验收测试

    更换驱动模块后,230650报警必须进行验收测试,处理方法 最佳答案 更改驱动设备,安全集成报警,需要做下调试菜单中的安全集成确认 提问者对于答案的评价:3q3q

    SINUMERIK 2017年6月3日