571.4的NCU 总清后重传程序后出现810004的报警

下面是诊断信息,请版主及各路高手帮忙分析是不是硬件有错误。

 

 

 Diagnostic buffer of module PLC 314C-2 DP

 

 Order No./ Des cription         Component                      Version                       

 6FC5 314-6CF00-0AB0            Hardware                       1410                          

 10.60.22  27.01.2005           Firmware                       V 1.0.5                       

 

 Rack:                          0

 Slot:                          2

 

 

 Event 1 of 100:  Event ID 16# 457F

 STOP caused by STOP command 

 Breakpoint in user program: Startup OB(OB 100) 

 Priority class:   27

 Previous operating mode: STARTUP (warm restart)

 Requested operating mode: STOP (internal)

 Internal error, Incoming event

 01:24:10.843 PM  02/15/2009

 

 

 Event 2 of 100:  Event ID 16# 1382

 Request for automatic warm restart 

 STOP due to: STOP caused by STOP command

 Startup information:

 - Startup without modified system configuration

 - No difference between setpoint and actual configuration

 - Time for time stamp at the last backed up power on

 - Single processor operation

 Current/last startup type:

 - Automatic warm restart after backed up power on

 Permissibility of certain startup types: 

 - Manual warm restart permitted

 - Automatic warm restart permitted

 Last valid operation or setting of the automatic startup type at power on:

 - Automatic warm restart after backed up power on

 Requested OB: Startup OB (OB100)

 Priority class: 27

 Incoming event

 01:24:10.834 PM  02/15/2009

 

 

 Event 3 of 100:  Event ID 16# 4301

 Mode transition from STOP to STARTUP 

 STOP due to: STOP caused by STOP command

 Startup information: 

 - Time for time stamp at the last backed up power on

 - Single processor operation

 Current/last startup type:

 - Automatic warm restart after backed up power on

 Permissibility of certain startup types: 

 - Manual warm restart permitted

 - Automatic warm restart permitted

 Last valid operation or setting of the automatic startup type at power on:

 - Automatic warm restart after backed up power on

 Previous operating mode: STOP (internal)

 Requested operating mode: STARTUP (warm restart)

 Incoming event

 01:24:10.631 PM  02/15/2009

 

 

 Event 4 of 100:  Event ID 16# 4300

 Power on backed up 

 Previous operating mode: No voltage

 Requested operating mode: STOP (own initialization)

 Incoming event

 01:24:00.533 PM  02/15/2009
 状态栏显示:

 Module available and o.k.

 Error LED (SF) 
 总清后面板上2个绿灯亮,重传程序后PLC侧的红灯PS,PF长亮,出现2000,3000,810004的报警。换到别的机床上重传也是一样的报警。 

 我是第一次接触571.4,不知道数据备份和重传和571.2,571.3是不是完全一样的?

问题补充:
今天机床厂的工程师已经弄好了,我不在场,很保守,具体的不说,估计是改的OB100,Breakpoint in user program: Startup OB(OB 100) 为什么重传后出现报警?出现报警后在别的机床上重传也会报警,会不会是机床厂在提供的机床程序上就动过手脚?

 

最佳答案

NCU的版本基本差不多,都一样。
 问题出在你传的程序是否对,程序硬件组态存在问题。
 NC 数据应该没问题。
 