【US2:22IP320L81】STARTER,FVR,S3.5,THOLR,277VAC,N12

【US2:22IP320L81】STARTER,FVR,S3.5,THOLR,277VAC,N12

Reversing motor starter Size 3 1/2 Three phase full voltage Amb compensate bimetal OLrelay Contactor amp rating 115Amp 240VAC 50HZ / 277VAC 60HZ coil Non-combination type Enclosure NEMA type 12 Dust/drip proof for indoors
product brand name Class 14 & 22
design of the product Full-voltage reversing motor starter
special product feature Half-size starter
General technical data
weight [lb] 53.8 lb
Height x Width x Depth [in] 25 × 17 × 7 in
touch protection against electrical shock NA for enclosed products
installation altitude [ft] at height above sea level maximum 6560 ft
ambient temperature [°F]
● during storage -22 … +149 °F
● during operation -4 … +104 °F
ambient temperature
● during storage -30 … +65 °C
● during operation -20 … +40 °C
country of origin USA
Horsepower ratings
yielded mechanical performance [hp] for 3-phase AC motor
● at 200/208 V rated value 30 hp
● at 220/230 V rated value 40 hp
● at 460/480 V rated value 75 hp
● at 575/600 V rated value 75 hp
Contactor
size of contactor Controller half size 3 1/2
number of NO contacts for main contacts 3
operating voltage for main current circuit at AC at 60 Hz maximum 600 V
operational current at AC at 600 V rated value 115 A
mechanical service life (operating cycles) of the main contacts typical 5000000
Auxiliary contact
number of NC contacts at contactor for auxiliary contacts 0
number of NO contacts at contactor for auxiliary contacts 1
number of total auxiliary contacts maximum 7
contact rating of auxiliary contacts of contactor according to UL 10A@600VAC (A600), 5A@600VDC (P600)
Coil
type of voltage of the control supply voltage AC
control supply voltage
● at AC at 50 Hz rated value 240 V
● at AC at 60 Hz rated value 277 V
holding power at AC minimum 14 W
apparent pick-up power of magnet coil at AC 310 VA
apparent holding power of magnet coil at AC 26 VA
operating range factor control supply voltage rated value of magnet coil 0.85 … 1.1
percental drop-out voltage of magnet coil related to the input voltage 50 %
ON-delay time 26 … 41 ms
OFF-delay time 14 … 19 ms
Overload relay
product function
● overload protection Yes
● test function Yes
● external reset Yes
reset function Manual and automatic
adjustment range of thermal overload trip unit 0.85 … 1.15
number of NC contacts of auxiliary contacts of overload relay 3
number of NO contacts of auxiliary contacts of overload relay 0
operational current of auxiliary contacts of overload relay
● at AC at 600 V 5 A
● at DC at 250 V 5 A
contact rating of auxiliary contacts of overload relay according to UL 5A@600VAC (B600), 5A@250VDC (P300)
Enclosure
degree of protection NEMA rating 12
design of the housing dustproof and drip-proof for indoor use
Mounting/wiring
mounting position Vertical
fastening method Surface mounting and installation
type of electrical connection for supply voltage line-side Box lug
tightening torque [lbf·in] for supply 120 … 120 lbf·in
temperature of the conductor for supply maximum permissible 75 °C
material of the conductor for supply AL or CU
type of electrical connection for load-side outgoing feeder Screw-type terminals
tightening torque [lbf·in] for load-side outgoing feeder 35 … 50 lbf·in
type of electrical connection of magnet coil Screw-type terminals
tightening torque [lbf·in] at magnet coil 5 … 12 lbf·in
type of connectable conductor cross-sections of magnet coil at AWG cables single or multi-stranded 2x (16 … 12 AWG)
temperature of the conductor at magnet coil maximum permissible 75 °C
material of the conductor at magnet coil CU
type of electrical connection for auxiliary contacts Screw-type terminals
tightening torque [lbf·in] at contactor for auxiliary contacts 10 … 15 lbf·in
type of connectable conductor cross-sections at contactor at AWG cables for auxiliary contacts single or multi-stranded 1x (12 AWG), 2x (16 … 14 AWG), 2x (18 … 16 AWG)
temperature of the conductor at contactor for auxiliary contacts maximum permissible 75 °C
material of the conductor at contactor for auxiliary contacts CU
type of electrical connection at overload relay for auxiliary contacts Screw-type terminals
tightening torque [lbf·in] at overload relay for auxiliary contacts 5 … 12 lbf·in
type of connectable conductor cross-sections at overload relay at AWG cables for auxiliary contacts single or multi-stranded 2x (16 … 12 AWG)
temperature of the conductor at overload relay for auxiliary contacts maximum permissible 75 °C
material of the conductor at overload relay for auxiliary contacts CU
Short-circuit current rating
design of the fuse link for short-circuit protection of the main circuit required 10kA@600V (Class H or K); 100kA@600V (Class R or J)
design of the short-circuit trip Thermal magnetic circuit breaker
maximum short-circuit current breaking capacity (Icu)
● at 240 V 14 kA
● at 480 V 10 kA
● at 600 V 10 kA
certificate of suitability NEMA ICS 2; UL 508; CSA 22.2, No.14
Further information
Industrial Controls – Product Overview (Catalogs, Brochures,…)
Industry Mall (Online ordering system)
Service&Support (Manuals, Certificates, Characteristics, FAQs,…)
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, …)
Certificates/approvals

US2:22IP320L81

US2:22IP320L81

US2:22IP320L81

last modified: 1/25/2022
Date
5/20/2023
Subject to change without notice
© Copyright Siemens 2023