【US2:18DUC82WH】STARTER,COMBO SZ1,3-12AMPS,N4SS,480V

【US2:18DUC82WH】STARTER,COMBO SZ1,3-12AMPS,N4SS,480V

Non-reversing motor starter Size 1 Three phase full voltage Solid-state overload relay OLRelay amp range 3-12A 380-440/440-480V 50/60HZ coil Combination type 10Amp circuit breaker Encl NEMA type 4X 304 S-steel Water/dust tight noncorrosive Extra-wide enclosure
product brand name Class 18 & 26
design of the product Full-voltage non-reversing motor starter with motor circuit protector
special product feature ESP200 overload relay
General technical data
Height x Width x Depth [in] 24 × 20 × 8 in
touch protection against electrical shock NA for enclosed products
installation altitude [ft] at height above sea level maximum 6560 ft
ambient temperature [°F]
● during storage -22 … +149 °F
● during operation -4 … +104 °F
ambient temperature
● during storage -30 … +65 °C
● during operation -20 … +40 °C
Horsepower ratings
yielded mechanical performance [hp] for 3-phase AC motor
● at 200/208 V rated value 2 hp
● at 220/230 V rated value 2 hp
● at 460/480 V rated value 5 hp
● at 575/600 V rated value 5 hp
Contactor
size of contactor NEMA controller size 1
number of NO contacts for main contacts 3
operating voltage for main current circuit at AC at 60 Hz maximum 600 V
operational current at AC at 600 V rated value 27 A
mechanical service life (operating cycles) of the main contacts typical 10000000
Auxiliary contact
number of NC contacts at contactor for auxiliary contacts 0
number of NO contacts at contactor for auxiliary contacts 1
number of total auxiliary contacts maximum 8
contact rating of auxiliary contacts of contactor according to UL 10A@600VAC (A600), 5A@600VDC (P600)
Coil
type of voltage of the control supply voltage AC
control supply voltage
● at AC at 50 Hz rated value 380 … 440 V
● at AC at 60 Hz rated value 440 … 480 V
holding power at AC minimum 8.6 W
apparent pick-up power of magnet coil at AC 218 VA
apparent holding power of magnet coil at AC 25 VA
operating range factor control supply voltage rated value of magnet coil 0.85 … 1.1
percental drop-out voltage of magnet coil related to the input voltage 50 %
ON-delay time 19 … 29 ms
OFF-delay time 10 … 24 ms
Overload relay
reset function Manual, automatic and remote
trip class CLASS 5 / 10 / 20 (factory set) / 30
adjustable current response value current of the current-dependent overload release 3 … 12 A
make time with automatic start after power failure maximum 3 s
relative repeat accuracy 1 %
number of NC contacts of auxiliary contacts of overload relay 1
number of NO contacts of auxiliary contacts of overload relay 1
operational current of auxiliary contacts of overload relay
● at AC at 600 V 5 A
● at DC at 250 V 1 A
contact rating of auxiliary contacts of overload relay according to UL 5A@600VAC (B600), 1A@250VDC (R300)
insulation voltage (Ui)
● with single-phase operation at AC rated value 600 V
● with multi-phase operation at AC rated value 300 V
Enclosure
degree of protection NEMA rating 4X, 304 stainless steel
design of the housing dustproof, waterproof & resistant to corrosion
Circuit Breaker
type of the motor protection Motor circuit protector (magnetic trip only)
operational current of motor circuit breaker rated value 10 A
adjustable current response value current of instantaneous short-circuit trip unit 30 … 100 A
Mounting/wiring
mounting position Vertical
fastening method Surface mounting and installation
type of electrical connection for supply voltage line-side Box lug
type of connectable conductor cross-sections at line-side at AWG cables single or multi-stranded 1x (14 AWG … 10 AWG) or 1x (12 AWG … 10 AWG)
temperature of the conductor for supply maximum permissible 75 °C
material of the conductor for supply AL or CU
type of electrical connection for load-side outgoing feeder Screw-type terminals
tightening torque [lbf·in] for load-side outgoing feeder 35 … 35 lbf·in
type of connectable conductor cross-sections at AWG cables for load-side outgoing feeder single or multi-stranded 1x (14 … 2 AWG)
temperature of the conductor for load-side outgoing feeder maximum permissible 75 °C
material of the conductor for load-side outgoing feeder AL or CU
type of electrical connection of magnet coil Screw-type terminals
tightening torque [lbf·in] at magnet coil 5 … 12 lbf·in
type of connectable conductor cross-sections of magnet coil at AWG cables single or multi-stranded 2x (16 … 12 AWG)
temperature of the conductor at magnet coil maximum permissible 75 °C
material of the conductor at magnet coil CU
type of electrical connection for auxiliary contacts Screw-type terminals
tightening torque [lbf·in] at contactor for auxiliary contacts 10 … 15 lbf·in
type of connectable conductor cross-sections at contactor at AWG cables for auxiliary contacts single or multi-stranded 1x (12 AWG), 2x (16 … 14 AWG), 2x (18 … 16 AWG)
temperature of the conductor at contactor for auxiliary contacts maximum permissible 75 °C
material of the conductor at contactor for auxiliary contacts CU
type of electrical connection at overload relay for auxiliary contacts Screw-type terminals
tightening torque [lbf·in] at overload relay for auxiliary contacts 7 … 10 lbf·in
type of connectable conductor cross-sections at overload relay at AWG cables for auxiliary contacts single or multi-stranded 2x (20 … 14 AWG)
temperature of the conductor at overload relay for auxiliary contacts maximum permissible 75 °C
material of the conductor at overload relay for auxiliary contacts CU
Short-circuit current rating
design of the short-circuit trip Instantaneous trip circuit breaker
maximum short-circuit current breaking capacity (Icu)
● at 240 V 100 kA
● at 480 V 100 kA
● at 600 V 25 kA
certificate of suitability NEMA ICS 2; UL 508; CSA 22.2, No.14
Further information
Industrial Controls – Product Overview (Catalogs, Brochures,…)
Industry Mall (Online ordering system)
Service&Support (Manuals, Certificates, Characteristics, FAQs,…)
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, …)
Certificates/approvals

US2:18DUC82WH

US2:18DUC82WH

US2:18DUC82WH

last modified: 1/25/2022
Date
5/20/2023
Subject to change without notice
© Copyright Siemens 2023