【US2:73FR36BFA】3RW40,15HP,58A,208V,N1,COMP. ENCL.

【US2:73FR36BFA】3RW40,15HP,58A,208V,N1,COMP. ENCL.

Enclosed soft starter, Controller 3RW40371BB14, Std. duty rating 15HP @200V, Std. duty current rating 58A Control voltage 110-230 AC/DC Enclosure NEMA type 1, Indoor general purpose use
product brand name Class 73
design of the product Enclosed soft starter
special product feature Control transformer, built-in overload relay and bypass contactor included.
General technical data
weight [lb] 56 lb
Height x Width x Depth [in] 25 × 18 × 13 in
touch protection against electrical shock NA for enclosed products
installation altitude [ft] at height above sea level maximum 6560 ft
ambient temperature [°F]
● during storage -22 … +149 °F
● during operation -4 … +104 °F
ambient temperature
● during storage -30 … +65 °C
● during operation -20 … +40 °C
country of origin USA
Power and control electronics
manufacturer’s article number of soft starter 3RW40371BB14
number of poles for main current circuit 3
design of power semiconductors (thyristors) for soft starter control 2 controlled phases
operating range factor supply voltage rated value 0.85 … 1.1
operating range factor of control voltage rated value 0.85 … 1.1
operating condition for standard duty Class 10 standard duty (350% of motor FLA for 10 seconds)
operating condition for severe duty NA
Features and functions
ramp-up (soft starting)/ramp-down (soft stop) Yes
starting voltage [%] 40 … 100 %
stopping voltage [%] 40 … 100 %
voltage ramp Yes
ramp-up time 0 … 20 s
ramp-down time 0 … 20 s
torque control No
adjustable current limitation Yes
creep speed in both directions of rotation No
pump ramp down No
integrated bypass contact system Yes
external isolation contactor Yes
intrinsic device protection Yes
overload protection Yes
trip class CLASS 5 / 15 / 20
reset function Manual, automatic and remote
thermistor motor protection No
inside-delta circuit No
breakaway pulse No
DC braking No
combined braking No
motor heating No
configuration of control input 1 ON / OFF
configuration of control input 2 NA
configuration of control input 3 NA
configuration of control input 4 NA
configuration of relay output 1 ON / RUN
configuration of relay output 2 BYPASSED
configuration of relay output 3 OVERLOAD / FAILURE
configuration of relay output 4 NA
display version 4 LEDs
operating measured value display No
product extension optional human machine interface module No
type of communication optional None
error logbook No
event list No
slave pointer function No
trace function No
number of parameter sets 1
engineering software (Soft Starter ES) No
disconnector functionality No
Contactor
size of contactor NA
Coil
type of voltage of the control supply voltage AC/DC
control supply voltage
● at DC rated value 110 … 230 V
● at AC at 50 Hz rated value 110 … 230 V
● at AC at 60 Hz rated value 110 … 230 V
Enclosure
degree of protection NEMA rating 1
degree of protection NEMA rating of the enclosure NEMA Type 1
design of the housing indoors, usable on a general basis
type of cooling None
Mounting/wiring
mounting position Vertical
fastening method Surface mounting and installation
wire length between motor starter and motor maximum 300 m
type of electrical connection for supply voltage line-side Box lug
type of connectable conductor cross-sections at line-side at AWG cables single or multi-stranded 2/0 … 14 AWG
temperature of the conductor for supply maximum permissible 75 °C
material of the conductor for supply CU
type of electrical connection for load-side outgoing feeder Box lug
tightening torque [lbf·in] for load-side outgoing feeder 40 … 40 lbf·in
type of connectable conductor cross-sections at AWG cables for load-side outgoing feeder single or multi-stranded 18 … 2 AWG (front only) or 16 … 2 AWG (back only) or 2x (16 … 2 AWG) (both front & back)
temperature of the conductor for load-side outgoing feeder maximum permissible 75 °C
material of the conductor for load-side outgoing feeder CU
type of electrical connection for auxiliary and control circuit screw-type terminals
tightening torque [lbf·in] for auxiliary and control contacts with screw-type terminals 7 … 10 lbf·in
temperature of the conductor for auxiliary and control contacts maximum permissible 75 °C
material of the conductor for auxiliary and control contacts CU
Short-circuit current rating
design of the fuse link for short-circuit protection of the main circuit required 10kA@600V (Class H or K); 100kA@600V (Class R or J)
design of the short-circuit trip Thermal magnetic circuit breaker
maximum short-circuit current breaking capacity (Icu)
● at 240 V 42 kA
● at 480 V 42 kA
● at 600 V 0 kA
certificate of suitability NEMA ICS 2; UL 508A
Further information
Industrial Controls – Product Overview (Catalogs, Brochures,…)
Industry Mall (Online ordering system)
Service&Support (Manuals, Certificates, Characteristics, FAQs,…)
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, …)
Certificates/approvals

US2:73FR36BFA

US2:73FR36BFA

US2:73FR36BFA

last modified: 1/25/2022
Date
5/20/2023
Subject to change without notice
© Copyright Siemens 2023