【US2:74AS36EFAF】SOFTSTART,FS,117A,200V,N4,3RW40

【US2:74AS36EFAF】SOFTSTART,FS,117A,200V,N4,3RW40

Enclosed soft starter, Controller 3RW40556BB34, Std duty rating 30HP @200V, Std duty current rating 117A Control voltage 115Vac Combination type, 200A fusible disconnect, Encl. type 4 painted steel, Water/dust tight for outdoors
product brand name Class 74
design of the product Enclosed soft starter with fusible disconnect switch
special product feature Control transformer, built-in overload relay and bypass contactor included.
General technical data
weight [lb] 142 lb
Height x Width x Depth [in] 50 × 25 × 20 in
touch protection against electrical shock NA for enclosed products
installation altitude [ft] at height above sea level maximum 6560 ft
ambient temperature [°F]
● during storage -22 … +149 °F
● during operation -4 … +104 °F
ambient temperature
● during storage -30 … +65 °C
● during operation -20 … +40 °C
country of origin USA
Power and control electronics
manufacturer’s article number of soft starter 3RW40556BB34
number of poles for main current circuit 3
design of power semiconductors (thyristors) for soft starter control 2 controlled phases
operating range factor supply voltage rated value 0.85 … 1.1
operating range factor of control voltage rated value 0.85 … 1.1
operating condition for standard duty Class 10, standard-compliant startup
operating condition for severe duty Class 20 severe duty (350% of motor FLA for 20 seconds)
Features and functions
ramp-up (soft starting)/ramp-down (soft stop) Yes
starting voltage [%] 40 … 100 %
stopping voltage [%] 40 … 100 %
voltage ramp Yes
ramp-up time 0 … 20 s
ramp-down time 0 … 20 s
torque control No
adjustable current limitation Yes
creep speed in both directions of rotation No
pump ramp down No
integrated bypass contact system Yes
external isolation contactor No
intrinsic device protection Yes
overload protection Yes
trip class CLASS 5 / 15 / 20
reset function Manual, automatic and remote
remote reset function No
thermistor motor protection No
inside-delta circuit No
breakaway pulse No
DC braking No
combined braking No
motor heating No
configuration of control input 1 ON / OFF
configuration of control input 2 NA
configuration of control input 3 NA
configuration of control input 4 NA
configuration of relay output 1 ON / RUN
configuration of relay output 2 BYPASSED
configuration of relay output 3 OVERLOAD / FAILURE
configuration of relay output 4 NA
display version 4 LEDs
operating measured value display No
product extension optional human machine interface module No
type of communication optional None
error logbook No
event list No
slave pointer function No
trace function No
number of parameter sets 1
engineering software (Soft Starter ES) No
disconnector functionality Yes
Contactor
size of contactor NA
Coil
type of voltage of the control supply voltage AC
control supply voltage
● at AC at 50 Hz rated value 115 V
● at AC at 60 Hz rated value 115 V
Disconnect Switch
response value of switch disconnector 200A / 600V
design of fuse holder Class R fuse clips
operating class of the fuse link Class R
Enclosure
degree of protection NEMA rating 4
degree of protection NEMA rating of the enclosure NEMA Type 4
design of the housing dustproof, waterproof & weatherproof
type of cooling None
Mounting/wiring
mounting position Vertical
fastening method Surface mounting and installation
wire length between motor starter and motor maximum 300 m
type of electrical connection for supply voltage line-side Box lug
type of connectable conductor cross-sections at line-side at AWG cables single or multi-stranded 1x (6 AWG … 300 Kcmil)
temperature of the conductor for supply maximum permissible 75 °C
material of the conductor for supply AL or CU
type of electrical connection for load-side outgoing feeder Box lug
tightening torque [lbf·in] for load-side outgoing feeder 90 … 110 lbf·in
type of connectable conductor cross-sections at AWG cables for load-side outgoing feeder single or multi-stranded 7 … 2/0 AWG (front only) or 6 … 2/0 AWG (back only) or 2x 1/0 AWG (both front & back)
temperature of the conductor for load-side outgoing feeder maximum permissible 75 °C
material of the conductor for load-side outgoing feeder CU
type of electrical connection for auxiliary and control circuit Screw-type terminals
tightening torque [lbf·in] for auxiliary and control contacts with screw-type terminals 7 … 10 lbf·in
type of connectable conductor cross-sections at AWG cables for auxiliary and control contacts 2x (20 … 14 AWG)
temperature of the conductor for auxiliary and control contacts maximum permissible 75 °C
material of the conductor for auxiliary and control contacts CU
Short-circuit current rating
design of the fuse link for short-circuit protection of the main circuit required 10kA@600V (Class H or K); 100kA@600V (Class R or J)
certificate of suitability NEMA ICS 2; UL 508A
Further information
Industrial Controls – Product Overview (Catalogs, Brochures,…)
Industry Mall (Online ordering system)
Service&Support (Manuals, Certificates, Characteristics, FAQs,…)
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, …)
Certificates/approvals

US2:74AS36EFAF

US2:74AS36EFAF

US2:74AS36EFAF

last modified: 1/25/2022
Date
5/20/2023
Subject to change without notice
© Copyright Siemens 2023

原创文章,作者:[db:作者],如若转载,请注明出处:https://www.zhaoplc.com/plc834150.html

(0)
打赏 微信扫一扫 微信扫一扫 支付宝扫一扫 支付宝扫一扫
上一篇 2023年6月25日 上午9:21
下一篇 2023年6月25日 上午9:21

相关推荐

发表回复

登录后才能评论