Enclosed soft starter, Controller 3RW40556BB34, Std duty rating 30HP @200V, Std duty current rating 117A Control voltage 115Vac Combination type, 200A fusible disconnect, Encl. type 4 painted steel, Water/dust tight for outdoors | |
product brand name | Class 74 | |
design of the product | Enclosed soft starter with fusible disconnect switch | |
special product feature | Control transformer, built-in overload relay and bypass contactor included. | |
General technical data | ||
weight [lb] | 142 lb | |
Height x Width x Depth [in] | 50 × 25 × 20 in | |
touch protection against electrical shock | NA for enclosed products | |
installation altitude [ft] at height above sea level maximum | 6560 ft | |
ambient temperature [°F] | ||
● during storage | -22 … +149 °F | |
● during operation | -4 … +104 °F | |
ambient temperature | ||
● during storage | -30 … +65 °C | |
● during operation | -20 … +40 °C | |
country of origin | USA | |
Power and control electronics | ||
manufacturer’s article number of soft starter | 3RW40556BB34 | |
number of poles for main current circuit | 3 | |
design of power semiconductors (thyristors) for soft starter control | 2 controlled phases | |
operating range factor supply voltage rated value | 0.85 … 1.1 | |
operating range factor of control voltage rated value | 0.85 … 1.1 | |
operating condition for standard duty | Class 10, standard-compliant startup | |
operating condition for severe duty | Class 20 severe duty (350% of motor FLA for 20 seconds) | |
Features and functions | ||
ramp-up (soft starting)/ramp-down (soft stop) | Yes | |
starting voltage [%] | 40 … 100 % | |
stopping voltage [%] | 40 … 100 % | |
voltage ramp | Yes | |
ramp-up time | 0 … 20 s | |
ramp-down time | 0 … 20 s | |
torque control | No | |
adjustable current limitation | Yes | |
creep speed in both directions of rotation | No | |
pump ramp down | No | |
integrated bypass contact system | Yes | |
external isolation contactor | No | |
intrinsic device protection | Yes | |
overload protection | Yes | |
trip class | CLASS 5 / 15 / 20 | |
reset function | Manual, automatic and remote | |
remote reset function | No | |
thermistor motor protection | No | |
inside-delta circuit | No | |
breakaway pulse | No | |
DC braking | No | |
combined braking | No | |
motor heating | No | |
configuration of control input 1 | ON / OFF | |
configuration of control input 2 | NA | |
configuration of control input 3 | NA | |
configuration of control input 4 | NA | |
configuration of relay output 1 | ON / RUN | |
configuration of relay output 2 | BYPASSED | |
configuration of relay output 3 | OVERLOAD / FAILURE | |
configuration of relay output 4 | NA | |
display version | 4 LEDs | |
operating measured value display | No | |
product extension optional human machine interface module | No | |
type of communication optional | None | |
error logbook | No | |
event list | No | |
slave pointer function | No | |
trace function | No | |
number of parameter sets | 1 | |
engineering software (Soft Starter ES) | No | |
disconnector functionality | Yes | |
Contactor | ||
size of contactor | NA | |
Coil | ||
type of voltage of the control supply voltage | AC | |
control supply voltage | ||
● at AC at 50 Hz rated value | 115 V | |
● at AC at 60 Hz rated value | 115 V | |
Disconnect Switch | ||
response value of switch disconnector | 200A / 600V | |
design of fuse holder | Class R fuse clips | |
operating class of the fuse link | Class R | |
Enclosure | ||
degree of protection NEMA rating | 4 | |
degree of protection NEMA rating of the enclosure | NEMA Type 4 | |
design of the housing | dustproof, waterproof & weatherproof | |
type of cooling | None | |
Mounting/wiring | ||
mounting position | Vertical | |
fastening method | Surface mounting and installation | |
wire length between motor starter and motor maximum | 300 m | |
type of electrical connection for supply voltage line-side | Box lug | |
type of connectable conductor cross-sections at line-side at AWG cables single or multi-stranded | 1x (6 AWG … 300 Kcmil) | |
temperature of the conductor for supply maximum permissible | 75 °C | |
material of the conductor for supply | AL or CU | |
type of electrical connection for load-side outgoing feeder | Box lug | |
tightening torque [lbf·in] for load-side outgoing feeder | 90 … 110 lbf·in | |
type of connectable conductor cross-sections at AWG cables for load-side outgoing feeder single or multi-stranded | 7 … 2/0 AWG (front only) or 6 … 2/0 AWG (back only) or 2x 1/0 AWG (both front & back) | |
temperature of the conductor for load-side outgoing feeder maximum permissible | 75 °C | |
material of the conductor for load-side outgoing feeder | CU | |
type of electrical connection for auxiliary and control circuit | Screw-type terminals | |
tightening torque [lbf·in] for auxiliary and control contacts with screw-type terminals | 7 … 10 lbf·in | |
type of connectable conductor cross-sections at AWG cables for auxiliary and control contacts | 2x (20 … 14 AWG) | |
temperature of the conductor for auxiliary and control contacts maximum permissible | 75 °C | |
material of the conductor for auxiliary and control contacts | CU | |
Short-circuit current rating | ||
design of the fuse link for short-circuit protection of the main circuit required | 10kA@600V (Class H or K); 100kA@600V (Class R or J) | |
certificate of suitability | NEMA ICS 2; UL 508A | |
Further information | ||
Industrial Controls – Product Overview (Catalogs, Brochures,…)
www.usa.siemens.com/iccatalog
|
||
Industry Mall (Online ordering system)
https://mall.industry.siemens.com/mall/en/us/Catalog/product?mlfb=US2:74AS36EFAF
|
||
Service&Support (Manuals, Certificates, Characteristics, FAQs,…)
https://support.industry.siemens.com/cs/US/en/ps/US2:74AS36EFAF
|
||
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, …)
http://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=US2:74AS36EFAF&lang=en
|
||
Certificates/approvals
https://support.industry.siemens.com/cs/US/en/ps/US2:74AS36EFAF/certificate
|
||
|
||
|
||
|
||
last modified: | 1/25/2022 | |
Date 5/20/2023 |
Subject to change without notice © Copyright Siemens 2023 |