【US2:14HP32AL81】STARTER-FVNR,SZ3,3PH,OPN,277V,

【US2:14HP32AL81】STARTER-FVNR,SZ3,3PH,OPN,277V,

Non-reversing motor starter, Size 3, Three phase full voltage, Amb compensate bimetal OLrelay Contactor amp rating 90Amp 240V 50HZ / 277V 60HZ coil, Non-combination type, Enclosure type (open), No enclosure
product brand name Class 14 & 22
design of the product Full-voltage non-reversing motor starter
General technical data
weight [lb] 8.1 lb
Height x Width x Depth [in] 10.66 × 6.75 × 5.19 in
touch protection against electrical shock Not finger-safe
installation altitude [ft] at height above sea level maximum 6560 ft
ambient temperature [°F]
● during storage -22 … +149 °F
● during operation -4 … +104 °F
ambient temperature
● during storage -30 … +65 °C
● during operation -20 … +40 °C
country of origin Mexico
Horsepower ratings
yielded mechanical performance [hp] for 3-phase AC motor
● at 200/208 V rated value 25 hp
● at 220/230 V rated value 30 hp
● at 460/480 V rated value 50 hp
● at 575/600 V rated value 50 hp
Contactor
size of contactor NEMA controller size 3
number of NO contacts for main contacts 3
operating voltage for main current circuit at AC at 60 Hz maximum 600 V
operational current at AC at 600 V rated value 90 A
mechanical service life (operating cycles) of the main contacts typical 5000000
Auxiliary contact
number of NC contacts at contactor for auxiliary contacts 0
number of NO contacts at contactor for auxiliary contacts 1
number of total auxiliary contacts maximum 7
contact rating of auxiliary contacts of contactor according to UL 10A@600VAC (A600), 5A@600VDC (P600)
Coil
type of voltage of the control supply voltage AC
control supply voltage
● at AC at 50 Hz rated value 240 V
● at AC at 60 Hz rated value 277 V
holding power at AC minimum 14 W
apparent pick-up power of magnet coil at AC 310 VA
apparent holding power of magnet coil at AC 26 VA
operating range factor control supply voltage rated value of magnet coil 0.85 … 1.1
percental drop-out voltage of magnet coil related to the input voltage 50 %
ON-delay time 26 … 41 ms
OFF-delay time 14 … 19 ms
Overload relay
product function
● overload protection Yes
● test function Yes
● external reset No
reset function Manual and automatic
adjustment range of thermal overload trip unit 0.85 … 1.15
number of NC contacts of auxiliary contacts of overload relay 3
number of NO contacts of auxiliary contacts of overload relay 0
operational current of auxiliary contacts of overload relay
● at AC at 600 V 5 A
● at DC at 250 V 5 A
contact rating of auxiliary contacts of overload relay according to UL 5A@600VAC (B600), 5A@250VDC (P300)
Enclosure
degree of protection NEMA rating Open device (no enclosure)
design of the housing NA
Mounting/wiring
mounting position Vertical
fastening method Surface mounting and installation
type of electrical connection for supply voltage line-side Box lug
tightening torque [lbf·in] for supply 120 … 120 lbf·in
temperature of the conductor for supply maximum permissible 75 °C
material of the conductor for supply AL or CU
type of electrical connection for load-side outgoing feeder Screw-type terminals
tightening torque [lbf·in] for load-side outgoing feeder 35 … 50 lbf·in
type of electrical connection of magnet coil Screw-type terminals
tightening torque [lbf·in] at magnet coil 5 … 12 lbf·in
type of connectable conductor cross-sections of magnet coil at AWG cables single or multi-stranded 2x (16 … 12 AWG)
temperature of the conductor at magnet coil maximum permissible 75 °C
material of the conductor at magnet coil CU
type of electrical connection for auxiliary contacts Screw-type terminals
tightening torque [lbf·in] at contactor for auxiliary contacts 10 … 15 lbf·in
type of connectable conductor cross-sections at contactor at AWG cables for auxiliary contacts single or multi-stranded 1x (12 AWG), 2x (16 … 14 AWG), 2x (18 … 16 AWG)
temperature of the conductor at contactor for auxiliary contacts maximum permissible 75 °C
material of the conductor at contactor for auxiliary contacts CU
type of electrical connection at overload relay for auxiliary contacts Screw-type terminals
tightening torque [lbf·in] at overload relay for auxiliary contacts 5 … 12 lbf·in
type of connectable conductor cross-sections at overload relay at AWG cables for auxiliary contacts single or multi-stranded 2x (16 … 12 AWG)
temperature of the conductor at overload relay for auxiliary contacts maximum permissible 75 °C
material of the conductor at overload relay for auxiliary contacts CU
Short-circuit current rating
design of the fuse link for short-circuit protection of the main circuit required 10kA@600V (Class H or K); 100kA@600V (Class R or J)
design of the short-circuit trip Thermal magnetic circuit breaker
maximum short-circuit current breaking capacity (Icu)
● at 240 V 14 kA
● at 480 V 10 kA
● at 600 V 10 kA
certificate of suitability NEMA ICS 2; UL 508; CSA 22.2, No.14
Further information
Industrial Controls – Product Overview (Catalogs, Brochures,…)
Industry Mall (Online ordering system)
Service&Support (Manuals, Certificates, Characteristics, FAQs,…)
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, …)
Certificates/approvals

US2:14HP32AL81

US2:14HP32AL81

US2:14HP32AL81

last modified: 4/27/2021
Date
5/20/2023
Subject to change without notice
© Copyright Siemens 2023

原创文章,作者:[db:作者],如若转载,请注明出处:https://www.zhaoplc.com/plc899326.html

(0)
打赏 微信扫一扫 微信扫一扫 支付宝扫一扫 支付宝扫一扫
上一篇 2023年7月14日
下一篇 2023年7月14日

相关推荐

发表回复

登录后才能评论